Panasonic 5 kW WH-WDG05LE5 + WH-ADC0509L3E5AN

Panasonic 5 kW WH-WDG05LE5 + WH-ADC0509L3E5AN

Power
5 kW
Availability
On order
Minimum order
1 pcs

Downloads

Price on request

We will check availability and get back to you with this information.

Nothing to pay now.

Description

Air-to-water heat pump Panasonic WH-WDG05LE5 + WH-ADC0509L3E5AN with 5 kW heating capacity, refrigerant R290 (propane), compressor: inverter. SCOP 5.06 (W35), COP 5.05 (A7/W35), energy class A+++, seasonal space heating efficiency ηs 200% (W35). Max. flow temperature 75 °C, min. outdoor operating temperature −25 °C, power supply single-phase, SG Ready. Outdoor unit: 996 × 980 × 430 mm (H × W × D), 98 kg, sound power level 52 dB(A).

Technical data

Main parameters

Heating capacity5 kW
Seasonal energy class (W35)A+++
SCOP (average climate, W35)5.06
RefrigerantR290 (propane)
Heat pump typeAir-to-water
Grid readiness (SG Ready)SG Ready
Seasonal space heating efficiency ηs (W35)200 %

Product details

COP (A7/W35)5.05
Cooling capacity5 kW
Max. flow water temperature75 °C
Min. outdoor operating temperature-25 °C
Compressor typeInverter
Refrigerant charge0.96 kg
Refrigerant GWP3
Number of phases1
Rated power input (heating)0.99 kW
COP (A-7/W35)3.01
COP (A2/W35 or B0/W35)3.52
Number of compressors1
Max. power input2.93 kW
Seasonal space heating efficiency ηs (W55)142 %
FunctionsHeating, cooling, DHW
Nominal water flow0.86 m³/h
AC input voltage220-240 V
Frequency50 Hz

Dimensions and weight

Sound power level, outdoor unit (LwA)52 dB(A)
Sound power level, indoor unit (LwA)41 dB(A)
Outdoor unit weight98 kg
Outdoor unit height996 mm
Outdoor unit width980 mm
Outdoor unit length430 mm